Chapter 7 Working With Cartridges and Barcodes
Barcode Requirements
Scalar i6000 User’s Guide 507
For SDLT I media barcodes, the library dynamically supports 1 to 6
characters for volume serial number plus a one-character media type
identifier. The image below is an example of a supported SDLT I barcode
label.
character media identifier
must be an “S”
For SDLT II media barcodes, the library dynamically supports 1 to 6
characters for volume serial number plus a one- character media type
identifier. The image below is an example of a supported SDLT II barcode
label.
character media identifier
must be a “2”
For DLT-S4 media barcodes, the library dynamically supports 1 to 6
characters for volume serial number plus a one-character media type
identifier. The media identifier should be “4”.
Quantum-supplied barcode labels will provid
e the best results. Barcode
labels from other sources can be used, but they must meet the following
requirements:
ANSI MH10.8M-1983 Standard
Number of digits: 6+1 (DLT) or 6+2 (LTO)
Background reflection: greater than 25 percent
Print contrast: greater than 75 percent
Ratio: greater than 2.2
Module: >= .254 mm
Print tolerance: ± 57 mm
Additional Requirements:
Height of the visible portion of the barcode: 10 mm ±2 mm