Chapter 5 Multi-Unit Commands
Configure Multi-Units (P4000/P7000)
Quantum P4000 and P7000 Libraries User’s Guide 87
Figure 50 Multi-Unit
Screen
Configure Multi-Units (P4000/P7000) 5
The
Configure Multi-Unit command allows you to set the following:
Library Unit field—sets whether the library is a slave or master in the
multi-unit configuration
Library Unit # field—sets the number assigned to a particular library
in the multi-unit configuration. Libraries are numbered left to right
beginning with 0 and ending with 4
# of Libraries field—sets the total number of libraries in the multi-unit
configuration
LUN Config field—this option is always set to Single LUN
To configure a Multi-Unit Library option:
1 In the
Multi-Unit screen, press the Configure Multi-Unit button.
The GUI displays the
Configure: Multi-Unit screen (see figure 51).
Multi-Unit
System
Off-line
Standby
Load Port
Operator Service
Multi
Unit
Back Forward
Home
O
Configure
Multi-Unit
Calibrate
All PTMs
Stop
About