6 Known Issues
43149 In some instances, during a drive firmware
update and associated drive reboot, a
diagnostic ticket reporting the drive has
been removed may be generated.
The drive should come back online
after the firmware update is
complete and the diagnostic ticket
will auto close. If not, follow the
directions on the diagnostic ticket to
troubleshoot.
50514,
50591
1647282,
1647440
MICA should only inform of multi-initiator
conflicts, not just multi-initiator operation
without reservations.
If multi-initiator operation without
reservations is being reported, you
can filter the diagnostic tickets.
From the GUI, configure the library to
enable diagnostic ticket filtering
(Setup > Notifications > Tickets
Filter).
53329 EEB attached IBM LTO-5 and LTO-6 drives
upgraded to latest drive firmware may
come up in the library in passive mode.
Reboot each drive individually. If that
doesn’t fix the issue, reboot the
library.
51994 When a drive sled is added to a partition it
may not appear in RES data.
Make sure that the robot(s) is
enabled and initialized before
physically adding the drive to the
library.
54091 During a backup, if the drive loses both FC
connections, failover will occur but the
media will not be moved to home slot.
To get the media to return to home
slot from Net back Up (NBU):
1 Select Devices > Robot.
2 Right click.
3 Select Change.
4 Browse to select robot device.
5 Click OK.
6 Click OK.
7 Click OK. Media is then put in it’s
home slot.
51702 During IVT, data pertaining to the drive-
side magazines in the right parking
module is not included in the report.
Make sure that the calibration targets
are located in the correct column and
row.
If calibration targets cannot be in
their proper position because of drive
location, you can move the drives to
different positions in the drive sled.