Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Known Issues 7
54202 If you disconnect the cable from a control
path drive that is connect to a host HBA,
the library will lose connectivity to the
robot.
1 Update path to robot.
2 run library audit
checklabel = barcode.
3 Media will now return to its home
slot.
4 Users are now able to run
simultaneous backups to both
drives without repairing FC
connection on Host HBA.
54220 If the control path drive fails over during
an import, any media in the picker will not
be discovered.
1 Run checkin libvolume search=yes
to pickup missing media
2 Then rerun the checkin libvolume
search=bulk to import remaining
media in I/E.
54580 A Series 3 control module may show the
presence of two CMBs even though there
is only one.
There is no negative effect to library
functionality. The second CMB listed
is actually the MCB.
54630 3948014 If the email addresses in the Contact tab
of the Notifications dialog and the Email
Notifications dialog are the same, an
email will ‘bounce’ (ie, undeliverable) and
fail to be delivered.
Check:
Setup > Notifications > System
Setup (Email Address field), and
Setup > Email Configuration
(Sender Address field)
54852 During a change to the internal IP of the
library the GUI can hang if you wait too
long to respond to dialog prompts.
Respond to the dialog prompts in a
timely manner. If you do wait too
long, reboot the library.
55202 When upgrading from i11.x to i12.x, all
ticket suppression filters will not be
restored. Restoring a configuration back to
i11.3 will also not restore the filters.
Before the upgrade, note which
filters you have set and then reset
them after the upgrade is complete.
55216 In libraries larger than 8 frames,
a geo-addressing issue may cause
diagnostic tickets related to CMBs and
HDCs to be generated in error.
Reboot the library.
55492 When upgrading from i11.3 to i12.2.1, the
partition is not mapped or listed in the
Access Group Configuration.
1 Go to Setup > SNW Wizard.
2 Click Next.
3 Select Host Access radio button.
4 Click Next.
5 Select Host Access Configuration.
6 Click Next.
7 Select Group.
8 Expand Tree.
Change
Request
Number
Service
Request
Number
Description Workaround