Page 122 DDS-4 SCSI Interface Manual, Rev. B
Field
Name
Bytes
Bits
Description
BOP bit 0 7 0 = The current logical position is not at BOT.
1 = The current logical position is at Beginning-of-Partition (BOT).
EOP bit 0 6
0 = The current logical position is not between early-warning and end-
of-tape.
1 = The current logical position is between early-warning and end-of-
tape.
MPU 0 3
0 = File Number field is valid.
1 = File Number field is invalid.
BPU 0 2
0 = Block Number field is valid.
1 = Block Number field is invalid.
Partition
Number
4-7 This field is always 0.
Block
Number
8-15 This field indicates the number of logical blocks including filemarks
between beginning-of-medium and the current logical position.
File
Number
16-23 This field indicates the number of filemarks between beginning-of-
medium and the current logical position.
Set
Number
24-31 This field indicates the number of setmarks between beginning-of-
medium and the current logical position.
Reserved All bits are 0.