Quantum DLT 7000 Handbuch Seite 151

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 312
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 150
SCSI Commands
Quantum DLT 7000 Tape System 5-47
LOG SENSE Command (4Dh) (continued)
Table 5–21 Log Parameters for Read / Write Error LOG SENSE Page Field Descriptions
(continued)
Field Name Description
TMC
(continued)
The criteria for comparison are:
Code - Basis of Comparison
00b - Every update of the cumulative value
01b - Cumulative value equal to threshold value
10b - Cumulative value not equal to threshold value
11b - Cumulative value greater than threshold value
LP List Parameter. This bit is 0 since the parameter codes are treated as data counters.
Parameter
Length
This field specifies the number of bytes of the parameter value.
Parameter
Value
This field indicates the actual value of this log parameter.