SDLT 220 and SDLT 320 Product Manual CHAPTER 5: Using Your Tape Drive
81-85002-01 March 2004 5-19
5.7.2 Over Temperature Condition
An Overtemp condition is defined to be when the calculated Tape Path Temp =
52 degrees C. When this condition is detected, the tape is rewound, unloaded, and
ejected from the drive. (As long as the drive is not mounted in a tape automation
library, the tape is ejected.) SCSI status will indicate the drive is in the over
temperature condition.
NOTE: If the drive is mounted in a tape automation library, the
tape is not automatically ejected; for details, refer to a
separate document, SDLT 220 and SDLT 320 Design and
Integration Guide, 81-81148-01.