Quantum SDLT 320 Betriebsanweisung Seite 98

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 102
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 97
CHAPTER 8: Insertion and Extraction Guidelines SDLT 220 and SDLT 320 Design & Integration Guide
8-10 March 2004 81-81148-01
Hold Time for Loading (Dwell Time)
When loading the cartridge into the drive, the maximum time that the picker
should hold the cartridge is 250 ms (0.25 second). If a longer hold time is used,
buckling and possible reel driver engagement problems could occur.
Debounce Time
The time allowed for the tape to stop moving (delay after insertion) is 50 ms.
Initialization Time
Initialization time is the maximum time for the SDLT 220/320 drive to come ready
after cartridge load; the time necessary for the drive to “ready itself” varies
according to the characteristics and history of the media:
Blank Media (never been written or degaussed): Typically when a blank
media is inserted into the drive, the drive completes its algorithms for
cartridge load within 1 ½ minutes. Worst case time for a blank media could be
up to 10 minutes. (This worst case time includes all of the error recovery
algorithms that may need to be invoked.)
Written Media: Typically when a written media is inserted into the drive, the
drive completes its algorithms for cartridge load within 15 seconds.