8.2.2.3 Software
An infrared port in the TVC unit allows the reading of data and performing the calibration via
an infra red reader connected to a portable PC running the Windows based software ‘Fuel
Monitor’, produced by E. Meurs BV. A typical data display is shown in figure 63
The software version number is: V1.01 and can be accessed with the ‘Fuel Monitor’ software,
or by viewing the LCD screen in the TVC unit where fitted.
8.2.2.4 Indication of measurement result
A legend shall be affixed adjacent to the volume indication clearly indicating that the volume
dispensed is corrected to 15 °C.
8.2.3 Adjustments
Adjustments to the calibration and temperature compensation of the TVC unit may be made
using a PC having an infra red link and running ‘Fuel Monitor’ software or using the scroll
buttons if the TVC unit has an LCD display.
8.2.4 Sealing
8.2.4.1 The TVC unit is sealed as shown in figure 61.
8.2.4.2 The temperature sensor is secured to prevent removal from the T-connector and
the T-connector from the fuel pipe by routing a sealing wire through the sensor and around the
pipe connection (figure 62).
8.2.6 Recommended tests
Check that the correct software version is installed in the TVC unit
9 CONNECTION TO MID APPROVED FUEL DISPENSERS AND SELF-
SERVICE DEVICE SYSTEMS
9.1 Fuel Dispensers
In addition to the dispensers already included in this approval, the system may also include
dispenser models which have been conformity assessed, and issued with a Type Examination
certificate, by a Notified Body responsible for Type Examination (Annex B) under Directive
2004/22/EC.
The dispensers may be as described in the following MID EC type-examination certificates:
T10001 - Fuel Dispensers
T10096 - LPG
T10105 - AdBlue