Pathlight VX User’s Guide 165
DPE—Back Panel Storage Processor LEDs
Each DPE storage processor (SP) provides seven status LEDs on the back panel, five of which provide
information. Figure 24
shows their location and Figure 19 describes their function.
Figure 24 Back Panel—DPE SP LEDs
Table 19 Back Panel—DPE SP Module LED Activity
LED Color State Description
BE 0 None OFF The designated connection is not active.
Green ON The designated connection is active.
FE 0 None OFF The designated connection is not active.
Green ON The designated connection is active.
FE 1 None OFF The designated connection is not active.
Green ON The designated connection is active.
Fault None OFF The SP is not experiencing any faults.
Amber Flashing 1x/4 sec BIOS activity
Flashing 1x/sec POST activity
Flashing 4x/sec Booting
Six fast flashes, long pause Rewriting BIOS/POST.
DO NOT REMOVE THE SP IN THIS
STATE.
Steady The SP is experiencing a fault.
Power None OFF The power is off.
Green ON The power is on.
Reserved None OFF Not applicable
Factory use only None OFF Not applicable
Note
If all LEDs are flashing, identify the specific DPE or DAE in the Pathlight VX
and contact ATAC. Refer to Getting More Information or Help
on page 4.
BE 1
FE 1
Fault
power
factory use only
reserved
FE 0