Chapter 2 Basic Library Operations
OCP Components
Quantum PX500 Series User’s Guide 67
1 From the Info screen, use the up and down arrows to highlight
Statistics and press Enter.
The Statistics screen displays (see figure 42):
Figure 42 Statistics Screen
The Statistics screen displays the following information about the
library:
ElapsTm – seconds since boot.
PCycles – total number of power cycles or reboots.
SlotGet – count of cartridge retrievals from slots.
SlotPut – count of cartridge deliveries to slots.
SltRetG – count of retries in retrievals from slots.
SltRetP – count of retries in deliveries to slots.
DrvGet – count of cartridge retrievals from drives.
DrvPut – count of cartridge deliveries to drives.
DrvRetG – count of retries in retrievals from drives.
DrvRetP – count of retries in deliveries to drives.
DrvLdR – count of retries for cartridge loads in drives.
DrvUnlR – count of retries for cartridge unloads in drives.
XYmove – count of horizontal moves.
Zmove – count of vertical moves.
Pmove – count of extension moves.
Rmove – count of rotation moves.
Exit