Scalar 24 Installation and Operation Guide 79
Configure I/E Slot
This option allows you to configure the I/E slot as either a storage slot or an Import/Export slot. If it is
configured as a storage slot, it will appear as a valid storage slot to the host application.
6 A confirmation screen displays. Press
to dismiss.
Selection Description/Result
1 From the Setup menu, highlight and
press .
Configures I/E slot.
2 Press and to select I/E slot.
3 Press to move to the next field.
4 Press and to select configuration
option.
Available options are:
• ST: appears as a valid storage location to
the host application (host will see 24 data
slots for LTO or 21 for SDLT). If partitioning
is enabled, this slot will be in Partition 1.
• I/E: host will see one import/export slot and
23 data slots for LTO or 20 for SDLT.
5 Press to highlight Execute ( ) and
then press .
The I/E slot is configured.