Scalar 24 Installation and Operation Guide 137
Vital Product Data Recovery
The Vital Product Data feature allows library settings to be automatically stored on the RMU. The feature
prevents customized settings, such as slot configurations, from being lost when the main board is replaced.
This feature works with LTO drive types only.
E9h Tape Recovered
to Cell X
Informational message that
indicates that a tape had
been detected in the picker
assembly and was placed in a
slot location (X) to free the
picker and make it
operational.
Make sure that the tape
belongs in the location it was
placed. You may have to use
the Move Media function to
move the tape to the proper
location.
E2h Security Alert
Check Door
The system has detected
operator interference, such as
an open door and magazine
removal, or a host has issued
a PREVENT MEDIA
REMOVAL and a tape has
been inserted or removed
from the I/E slot.
Check and ensure that
magazines are installed, the
door is closed, and that the
I/E slot is empty.
E3h,
E4h,
E5h, and
E6h
SCSI Error
Check SCSI
A SCSI connection problem
has been detected.
Make sure the cables are
connected correctly, the bus
type, LVD is connected
correctly, and the proper
terminator is applied.
F5h Clean Needed
Check Drive X
A drive has been cleaned, but
still requires cleaning. The
cleaning tape may not
function properly, may be
expired, or the drive may be
defective.
Retry the clean operation.
F6h Tape Expired
Eject Slot X
A cleaning tape is expired. Export the cleaning tape and
insert a new one.
F7h No Clean Tape
Insert Tape
A cleaning operation was
attempted, but a cleaning
tape is not configured,
expired, or not available.
Insert a cleaning tape into the
I/E slot or configure a
cleaning slot and import a
cleaning tape into that slot.
F8h Tape Missing
in Slot X
A previously configured
cleaning tape is no longer
found. It may have been
removed manually, loaded in
a drive, or placed in a data
slot.
Place the tape back into the
slot.
SAC
Code
Error Message Description Recommended Action