Chapter 3 Operation
Handling Operational Fault Conditions
GoVault™ for Windows User’s Guide 51
Table 2 Resolving Abnormal
Hardware Conditions
SMART Threshold
Detection 3
The GoVault system application software monitors the currently installed
cartridge for detection of a Self-Monitoring Analysis and Reporting
Technology (SMART) threshold once a minute. When it detects a SMART
threshold fault, the GoVault system application software displays a
SMART fault warning and:
• Posts a message in the Windows Application Event log
• Updates the GoVault Properties, setting the
SMART set status to Yes
(see figure 28
on page 45)
Contact Quantum Technical Support for diagnosis instructions.
IF a . . . problem occurs, THEN . . .
voltage shut down the computer and contact the
computer manufacturer for instructions
and diagnosis.
temperature check and make sure that the internal
GoVault dock fan is operational and the
exhaust air flow is not restricted or
blocked.
fan contact Quantum Technical Support for
diagnosis instructions.
Note: After the activity LED indicator begins flashing to signify an
abnormal hardware condition, it will not return to normal until
you shut down and restart the workstation or server system.