28 Installation
Verifying SNC 6101 Operation
Use the following procedures to verify SNC 6101 connections and configure the FC port, SNMP traps, and
e-mail alerts. Use the ADIC Management Console. For more information, refer to the ADIC Management
Console User’s Guide.
1 Using the ADIC Management Console, confirm that all attached devices are displayed under each
channel.
2 Verify/set configuration values for the FC Port. The speed and connectivity settings of the SNC 6101
default to auto detect and in most situations no additional configuration should be necessary. However,
if the install environment requires custom settings, you must confirm the following:
Speed: 1 GBps or 2 GBps (should match your LAN speed)
Connection Options: Point-to-Point for switch attachment, Loop for arbitrated loop attachment, and
Loop Preferred if the connection type is unknown (this mode will try a loop attachment first, followed by
a point-to-point attachment)
For more information about configuring advanced FC and SCSI parameters such as Loop ID and port
mode, refer to the ADIC Management Console User’s Guide.
3 Configure all SNMP traps with the AMC to generate proactive alerts for the Scalar 100. For more
information, refer to the ADIC Management Console User’s Guide.
4 Save your current configuration in case you need to restore it in the future. For more information, refer
to the ADIC Management Console User's Guide.
5 Configure e-mail alerts with the AMC to generate e-mail messages when the Scalar 100 encounters a
problem. For more information, refer to the ADIC Management Console User’s Guide.
CAUTION
Do not set Port Mode to Initiator for this library. Setting Mode to
Initiator will prevent hosts from seeing library drives and media
changer. Initiator mode makes the SNC appear as a host instead of a
storage device.