Chapter 4 SNMP Trap List
Quantum PX500 Series User’s Guide 156
Ralu rnd number
generator reset
The random number generator
used to calculate the slot locations
for the internal Random Access
Load Unload (RALU) function
has been reset.
Informational Diagnostics
Elem move failed limits
check
A move to an element failed a
calibration limit.
Warning Diagnostics
Hand-communication
fail
The communications to the
robotic hand has failed.
Warning Diagnostics
XYZ-communication fail The communication to the robotic
hardware for moving the X,Y and
Z axis has failed.
Warning Diagnostics
Timeout waiting for
response (status/taskId)
A command sent by the
diagnostics module has timed out
waiting for a return from another
module in the system.
Critical Diagnostics
Z-axis init fail The Z (vertical) axis initialization
routine has failed.
Critical Diagnostics
Z-motor fail (zone #) The robotic hand has failed to
position the vertical axis to a
predetermined physical location.
Critical Diagnostics
Z-position fail (zone #) The robotic hand has failed to
position the vertical axis to a
predetermined physical location.
Critical Diagnostics
X-position fail (zone #) The robotic hand has failed to
position the XY axis to a
predetermined physical location.
Critical Diagnostics
XY-home fail The XY axis initialization routine
has failed to find its home
position.
Critical Diagnostics
XY-motor fail (zone #) The robotic hand has failed to
position the XY axis to a
predetermined physical location.
Critical Diagnostics
Event Detail Event Description Category Reported By