Chapter 4 SNMP Trap List
Quantum PX500 Series User’s Guide 173
QSB Channel Errors
(channel/errors)
A QSB error has occurred. Warning Sys monitor
QSB Channel Failure
(channel/count)
A QSB failure has occurred. Critical Sys monitor
QSB Channel Resyncs
(channel/resyncs)
A QSB resync has occurred. Warning Sys monitor
RTC Failure The real time clock has failed. Critical Sys monitor
RTC Time not set The real time clock has not been
set.
Informational Sys monitor
Unknown board
revision(board/Board
Revision)
An unknown board revision has
been detected.
Critical Sys monitor
Wrong CPLD
revision(board/CPLD
Revision)
Wrong CPLD revision detected. Critical Sys monitor
ADC Sensor
Communication
Failed(channel/id)
The SPI flash has failed.
channel 0-1id
2 SPI_ID_BP_ADC_1
3 SPI_ID_BP_ADC_2
14 SPI_ID_BRM_ADC
Critical Sys monitor
BP is over
temperature(old temp/
new temp)
The backplane has experienced an
over-temp condition.
Critical Sys monitor
BRM is over
temperature(old temp/
new temp
The BRM has experienced an
over-temp condition.
Critical Sys monitor
BRM1 is over
temperature(old temp/
new temp)
The BRM1 has experienced an
over-temp condition.
Critical Sys monitor
Event Detail Event Description Category Reported By