68 Diagnostics Menu
dd = Drive number (01 - 02)
This function is usually used for diagnostics only by a trained technician.
Place In Slot
The Place In Slot function will cause the Media Picker to place the cartridge into a storage
slot.
Notes
If the optional barcode reader is installed, the available cartridge
storage slots are 2-18.
Slot # 12 is considered to be a storage slot for Diagnostics Menu
operations when the Virtual Mailbox Slot is enabled in the
Configuration Menu.
p Use LEFT or RIGHT to select the desired field. Select the row and slot using UP or
DOWN. Press ENTER to activate.
ss = Slot number (01 - 18)
This function is usually used for diagnostics only by a trained technician.
Place In Drive
The Place In Drive function will cause the drive door to open and the Media Picker to place
the cartridge into the drive.