Chapter 3 Operator Control Panel
Mode
34 Quantum|ATL PowerStor L200 Series Library Users Guide
Sequential NOT Selected
Sequential Circ NOT Selected
Autoload Cart: N
Enable Barcode: N
AutoClean: N
4 Press Enter to toggle the mode options.
Enter executes the Selected mode and toggles all other modes
to NOT Selected.
For example, if you toggle the Sequential mode to Selected, the
Random and Sequential Circ modes are automatically toggled
to NOT Selected
. Enter also toggles each of the Y and N
options.
5 Press Select to return to the main menu.
Optional
Autoclean Mode
3
If the optional autoclean is enabled, the time that a SCSI Move
Media command takes to complete increases from approximately
20 seconds to 60 seconds because the library must wait until
calibration is complete. If cleaning is required, the typical time
increases to a maximum of 10 minutes while the drive is cleaned.
To use:
1 Load the cleaning cartridge into slot 7.
2 Press Enter to enable AutoClean: Y.
When AutoClean is enabled, the status of slot 7 becomes
unviewable. The OCP cannot be used to load a cleaning cartridge.
After the manual cleaning cycle is complete, the second line of the
OCP will display an idle message. Turn off the library. Wait at
least ten seconds. Turn on the library. After the initialization
process is complete, set the AutoClean parameter to N. The
cleaning cartridge may then be ejected.