Chapter 5 Regulatory Compliance
Electromagnetic Field Specifications
SDLT 600 Product Manual 85
Immunity and ESD
Limits
5
Table 36 lists the immunity and ESD failure level limits to which the
SDLT 600 tape drive has been tested.
CNS 13438 BSMI Class A (Taiwan)
AS/NZS 3548 Australia/New Zealand
Test Name
Test
Specification
Required
Performance
EN55022: 1998 Radiated and Conducted Emissions
Radiated Electromagnetic
Emissions
EN55022: 1998 Class B
Conducted Electromagnetic
Emissions
Current Harmonics and Flicker Emissions Tests
AC Power Supply Harmonic
Emissions
EN61000-3-2 As per the
standard
AC Power Supply Voltage Flicker EN61000-3-3 As per the
standard
EN55024: 1998 Immunity Tests
Electrostatic Discharge Immunity EN61000-4-2 Criteria A
Radiated Electromagnetic
Immunity
EN61000-4-3 Criteria A
Electrical Fast Transient / Burst
Immunity
EN61000-4-4 Criteria B
Electrical Surge Immunity EN61000-4-5 Criteria B
Conducted Electromagnetic
Immunity
EN61000-4-6 Criteria A
Power Frequency Magnetic Field
Immunity
EN61000-4-8 Criteria A
Type Regulation/Certification