Quantum DLT 4000 Handbuch Seite 41

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 300
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 40
Hardware Implementation
Quantum DLT 4000 Tape Drive 2-7
2.2.3 Configure The Rackmount Drive for Parity Checking
The default setting for DLT 4000 tape drives is to have parity checking enabled.
If the system to which you are configuring the rackmount tape drive does not
generate SCSI parity, there are two ways that parity checking can be disabled.
You can disable parity checking by:
(a) Installing a jumper across Pins 1 and 2 on the parity check connector as
shown in Figure 2-2, or
(b) Installing a jumper across Pins 7 and 8 on the SCSI ID jumper block shown
in Figure 2-1.
2.2.4 Configure the Tabletop Drive
Figures 2-3 and 2-4 show the locations of the controls for the tabletop versions of
the drive. Note that these drives are normally configured to meet customer
specifications before they leave the factory so should not require any internal
configuration changes on-site.
Figure 2–3 Tabletop (Version 1) Back Panel Controls
SCSI ID Pushbutton