Chapter 2 Installing the L500 Series Library
Selecting an Installation Location
Quantum|ATL PowerStor L500 Series Tape Library Users Guide 17
Overhead
Clearance
2
The height of the stand-alone library is 18 inches (46 cm). The
height of the rack mount library is 7 inches (18 cm).
To remove and replace the library enclosure, you need an overhead
clearance slightly greater than the height of the library.
Surface Strength
and Inclination
2
Place the library and rack on a clean, level surface. If the library
will be placed on a desk or table, make sure it is sturdy enough to
support the librarys weight (76 lbs/35 kg).
Power and
Grounding
2
The electrical ratings for the library are 110 - 120/200 - 240 VAC,
50 Hz - 60 Hz, 1.6 A - 0.8 A, 140 W - 200 W.
Power Cord
2
A 110/120 VAC power cord is supplied with your unit. If your
country/locale does not use 110/120 VAC, refer to the criteria
listed below for parameters.
The power cord used with this equipment must meet the following
criteria:
The power cord should be a minimum of 18/3 AWG, 60
°C,
Type SJT or SVT.
UL and CSA Certified cordage rated for use at 250 VAC with a
current rating that is at least 125% of the current rating of the
product. In Europe, the cordage must have the HAR mark.
The plug must be terminated in a grounding-type male plug
designed for use in your country. It must also have marks
showing certification by an agency acceptable in the country.
Warning:
Do not attempt to modify or use an external 110 - 120
VAC power cord for 220 - 240 VAC input power.
Modifying the power cord can cause personal injury
and severe equipment damage.