Seitenansicht 92
Quantum|ATL PowerStor L500 Series Tape Library Users Guide 79
Radiated Susceptibility
5
The radiated susceptibility limits for high frequency electric fields,
26 MHz to 1000 MHz, are:
3 V/m (rms) 80% modulated 1 kHz
No errors, no screen distortion. S/W recoverable errors
No hardware failure
The transient voltage is the actual peak voltage above the normal
AC voltage from the power source.
The voltage limits for power and data cables are:
2 kV S/W recoverable errors
No hardware failures
The power cable voltage limits are:
2.0 kV common mode (no errors allowed)
1.0 kV differential mode (S/W recoverable errors, no hardware
failure)
ESD Failure Level
Limits
5
Table 21
lists the ESD failure level limits for normal operator access
areas.
Table 21 ESD Failure
Level Limits
Failure
Type Equipment
Failure
Level Allowable Errors
Hard Office To 12 kV No operator intervention (soft
recoverable allowed)
Hardware Office To 15 kV No component damage -
operator intervention allowed
(soft/hard errors allowed)