SCSI Commands
Quantum DLT 8000 Tape System 5-27
INQUIRY Command (12h) (continued)
Table 5–11 Identifier Descriptor — Field Descriptions
Field Name Description
Code Set The value in this field indicates the type of data to be found in the
Identifier field.
Code Meaning
1 Binary data
2 ASCII data
Association The value in this field indicates whether the Identifier is associated
with the logical unit (LUN) or the port. The default for this field = 0,
designating associating with the LUN.
Identifier Type Types of identifiers allowed are:
Value Description
1 Concatenation of the Vendor Name, Product ID, and unit
serial number
2 Canonical form of the IEEE Extended Unique Identifier, 64
bit (EIU-64)
3 FC-PH Name_Identifer
Identifier The value in this field indicates the Identifier, based on Identifier Type:
Identifier Type Code Set Length Identifier
1 2 24 Quantum DLT8000, 7 ASCII
space characters (20h),
followed by unit serial number
in ASCII
2 1 8 8 Bytes of binary data
indicating the EUI-64 assigned
to the drive
3 1 8 8 Bytes of binary data
indicating the 64-bit, Type 5,
FC-PH Name_Identifier assigned
to the drive