SCSI Commands
Quantum DLT 8000 Tape System 5-55
LOG SENSE Command (4Dh) (continued)
LOG PARAMETERS
Bit
Byte
7 6 5 4 3 2 1 0
0 -1
(MSB)
Parameter Code
(LSB)
2 DU DS TSD ETC TMC Rsv’d LP
3 Parameter Length
4 - n
(MSB)
Hex ASCII String for Event n
(LSB)
Figure 5–23 Log Parameters Format for LAST n ERROR EVENTS LOG SENSE Page
Table 5–23 Log Parameters for LAST n ERROR EVENTS LOG SENSE Page Field
Descriptions
Field Name Description
Parameter Code Parameter Code values are assigned from 0 to 27, where 0 is the
oldest event stored and the highest Parameter Code returned is the
most recent event.
Hex ASCII String for Event n The text of the parameter includes a “Packet #” that is a value from 0
to 255. This internal number is assigned when the packet is written to
EEPROM. A value of 0 is normally the oldest packet, but packet
numbers can wrap around back to 0 after reaching 255. For a
description of the packet string, see Appendix B.
For definitions of bits that make up the Control Byte (byte 2), refer to Section 5.8.3., Table 5-
21.