General Description and Specifications
Quantum DLT 8000 Tape System 1-17
Table 1−18 Conducted Susceptibility
NOTE
The transient voltage is the actual peak voltage above the normal ac voltage from
the power source.
Fast Transient (Bursts) for Power and Data Cables
2 kV S/W recoverable errors
No hardware failures
High Energy Transient Voltage for Power Cables *
1.2 kV
2.5 kV
No errors
S/W recoverable errors
No hardware failures
Low-level Conducted Interference
3 V (rms) 80% modulated 1
kHz
No errors
S/W recoverable errors
No hardware failures
Fast Transient (Bursts) for Power and Data Cables
2 kV S/W Recoverable errors
No hardware failures
Table 1−19 ESD Failure Level Limits
Failure Type Equipment Failure Level Allowable Errors
Hard Office 1 to 12 kV No Operator Intervention (soft recoverable
allowed)
Hardware Office Up to 15 kV No component damage – operator
intervention allowed (soft/hard errors
allowed)
Kommentare zu diesen Handbüchern