JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
10-15
WHAT THE LIBRARY RETURNS
Write Line 1 – Byte 02, Bit 3
This field indicates the type of text that appears on Display Line 1 of the LCD
Status Screen (bytes 04 through 19 of the LCD Mode page), as follows:
The factory default is 0. You can change this field with the MODE SELECT
command (see “LCD Mode Page (Page Code 22h)” on page 9-12).
Note: The text specified for Display Line 1 is displayed when the library does not
have any active status to display (that is, the cartridge loader is ready to
receive commands and there are no error conditions).
Display Line 1 – Bytes 04 through 24
This field indicates the text that will appear on line 1 of the LCD. Display
Line 1 is typically used to specify the product name displayed on the LCD.
Magnum 224, T24, or SL 2U—The default product name for the library is
“Magnum 224”. You can change this field with the MODE SELECT
command (see “LCD Mode Page (Page Code 22h)” on page 9-12).
Magnum 448—The default product name for the library is “Magnum 448”.
You can change this field with the MODE SELECT command (see “LCD
Mode Page (Page Code 22h)” on page 9-12).
10.3.7 CLEANING CONFIGURATION PAGE (PAGE CODE 25h)
The Cleaning Configuration page indicates how the library behaves when it is
configured to autoclean the tape drive.
Page Code – Byte 00, Bits 5 through 0
This field identifies the Clean Configuration page. The value of this field must
be 25h.
0 Library default text
1
Text you specified in bytes 04 through 19 of the MODE
SELECT LCD Mode page
Bit
Byte
7 6 5 4 3 2 1 0
00 Reserved Page Code (25h)
01 Page Length (02h)
02 Reserved Auto FixEnable
03 Cleaning Cartridge Storage Element
Kommentare zu diesen Handbüchern