Quantum LTO 2U Betriebsanleitung Seite 169

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 264
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 168
JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
15-19
WHAT THE LIBRARY RETURNS
If the installed tape drive supports the extended data, the ten-byte tape drive
serial number (as received from the tape drive via the serial port) is appended
to the standard data transfer element descriptor. If the library receives a READ
ELEMENT STATUS command before it has queried the tape drive, this field
contains UNKNOWN. If the tape drive does not support returning its serial
number to the library, this field contains ten blanks.
15.3.8 ASC AND ASCQ VALUES FOR ABNORMAL STATES
Table 15-2 contains a list of the ASC and ASCQ values that will appear in the
Additional Sense Code and Additional Sense Code Qualifier fields of an
element descriptor if the element is in an abnormal state. Table 15-2 also
indicates the corrective action for each abnormal state. The Except field of an
element descriptor indicates if the element is in an abnormal state.
Table 15-2 ASC and ASCQ values for abnormal element conditions
ASC ASCQ Description Corrective Action
83h 00h Label questionable The bar code label is questionable. Issue an INITIALIZE
ELEMENT STATUS (07h) or INITIALIZE ELEMENT STATUS
WITH RANGE (37h) command.
83h 01h Cannot read bar code
label or invalid
checksum value
Replace the label as described in the Magnum 224,
StorageLibrary T24, or StorageLoader 2U LTO Library Product
Manual or the Magnum 448 LTO Library Product Manual. If the
error still occurs and the label is correctly placed, contact your
vendor. For specifications for the bar code labels that can be
used with the library, refer to the Tandberg Data Bar Code Label
Specification for LTO Ultrium Cartridges.
83h 03h Label and full status
questionable
The library was powered on or the cartridge access port door
was opened. The cartridge inventory may have been violated.
Issue an INITIALIZE ELEMENT STATUS (07h) or INITIALIZE
ELEMENT STATUS WITH RANGE (37h) command.
Note: If the element is a tape drive that is empty or contains a
data cartridge (not ejected), issuing an INITIALIZE ELEMENT
STATUS or INITIALIZE ELEMENT STATUS WITH RANGE will
not change the questionability of the full status. You may want
to issue an UNLOAD command to the tape drive to determine
whether the tape drive is full or empty.
83h 04h Tape drive not
installed
There is no tape drive installed. Install a tape drive or ignore the
error.
83h 09h No bar code label If the cartridge does not have a bar code label, place a label on
the cartridge as described in the Magnum 224, StorageLibrary
T24, or StorageLoader 2U LTO Library Product Manual or the
Magnum 448 LTO Library Product Manual. If there is a bar code
label and it is placed correctly, contact your vendor. For
specifications for the bar code labels that can be used with the
library, refer to the Tandberg Data Bar Code Label Specification
for LTO Ultrium Cartridges.