Quantum LTO 2U Betriebsanleitung Seite 257

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 264
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 256
JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
A-25
ERRORS REPORTED OVER THE SCSI BUS
1Bh 87h 24h 4h D, L 8, 13, 12 Drive comm failed. The library is unable
to communicate with the tape drive.
1Ch 3Bh 0Dh 5h A, O 11, 6 Destination full. The destination element
was occupied for a MOVE MEDIUM
command. Redirect the cartridge loader
to a different location.
1Dh 3Bh 0Eh 5h A, O 11, 7 Source empty. The source element was
empty for a MOVE MEDIUM command.
Redirect the cartridge loader to a different
location.
1Eh 04h 8Eh 02h O 11, 2 Not Ready. Sequential mode. An
application tried to issue commands to
the library while it was in Sequential
mode.
1Fh 30h 00h 3h T, D 9, 14,
13, 12
Incompatible medium. (The media does
not have a compatible logical format.)
Incompatible media was ejected after a
LOAD command was issued.
Incompatible media was rejected after
the data cartridge was inserted.
1Fh 53h 00h 03h I 10 Media Load/Eject fail. Media removal
prevented.
20h 53h 00h 03h I 10 Media Load/Eject fail. Media removal
prevented.
21h 04h 8Dh 02h O 11, 2 Not Ready. Key mode. An application
tried to issue commands to the library
while it was being controlled from the
operator panel.
22h 04h 89h 02h O 11, 2 Not Ready. Console mode. An
application tried to issue commands to
the library while it was being controlled
from the Remote Management utility.
29h 3Bh 15h 02h O 11 Magazine is unlocked. Operator may
change cartridges and close magazine.
29h 40h D7h 02h O 11 EEPort is open.
Table A-4 REQUEST SENSE error information (FSC, ASC, ASCQ, and SK (continued)
FSC
ASC
(byte 12)
ASCQ
(byte 13)
Sense
Key
Cause ERP SCSI Error Message and Description
Seitenansicht 256

Kommentare zu diesen Handbüchern

Keine Kommentare