23-4
SCSI REFERENCE 1014826
CHAPTER 23—SEND VOLUME TAG (B6h)
Examples of valid templates are as follows:
23.4 COMMAND STATUS
The library returns a status byte after processing the SEND VOLUME TAG
command. This section describes when each type of status byte might be
returned.
Good
The library returns Good status when it is able to process the command
without errors.
Busy
Busy status indicates that the library is temporarily unable to accept a
command from this initiator. The initiator may retry the command later.
Reservation Conflict
The library returns Reservation Conflict status when it is reserved by a
different initiator. See Chapter 20 for more information about the RESERVE
command.
Check Condition
The library returns Check Condition status for the following reasons:
The command is issued to an invalid LUN.
A Unit Attention condition is pending for the initiator.
The library is not ready because a magazine is removed.
A reserved bit is set to 1 in the CDB or parameter list.
Template Matches
123?5678 12305678
12315678
and so on
123*5678 123___
(Any information starting with “123”; 5678 is ignored)