
A-24
SCSI REFERENCE 1014826
CHAPTER A—ERROR CODES
13h 3Fh 00h 6h S, O 11 Operating condition changed. Over
temperature. The library’s internal
temperature is at a unsafe level for the
media.
Wait until the library has cooled, then
unload the cartridge to a cell and re-load
it into the tape drive.
Check the room temperature. The
ambient temperature must be no more
than 40°C (104°F).
Provide additional air flow around the
library to improve cooling.
15h 3Fh 86h 4h L 8, 15, 12 Checksum miscompare. The flash
EEPROM checksum was bad.
16h 30h 00h 3h T, D 9, 14,
13, 12
Incompatible medium. (The media does
not have a compatible logical format.)
Incompatible media was ejected after a
LOAD command was issued.
Incompatible media was rejected after
the data cartridge was inserted.
17h 53h 02h 5h O, S, A 5, 8 Media removal not allowed. The library
cartridge access port door cannot be
opened because the operation was
prevented with a PREVENT/ALLOW
MEDIUM REMOVAL command.
18h 3Bh 0Dh 5h A, O 11, 6 Destination full. The destination element
was occupied for a MOVE MEDIUM
command. Redirect the cartridge loader
to a different location.
19h 3Bh 0Eh 5h A, O 11, 7 Source empty. The source element was
empty for a MOVE MEDIUM command.
Redirect the cartridge loader to a different
location.
1Ah 87h 26h 4h D, L 8, 13, 12 Drive command error. The tape drive
failed to respond to a command from the
library.
1Bh 87h 21h 4h D, L 8, 13, 12 Drive comm failed. The library is unable
to communicate with the tape drive.
1Bh 87h 23h 4h D, L 8, 13, 12 Drive comm timeout. The library is
unable to communicate with the tape
drive.
Table A-4 REQUEST SENSE error information (FSC, ASC, ASCQ, and SK (continued)
FSC
ASC
(byte 12)
ASCQ
(byte 13)
Sense
Key
Cause ERP SCSI Error Message and Description
Kommentare zu diesen Handbüchern