JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
19-11
WHAT THE LIBRARY RETURNS
SValid – Byte 09, Bit 7
This bit is set as follows:
Invert – Byte 09, Bit 6
The library uses single-sided media and does not support inverting of the
media (recording on both sides of the tape). The value reported for this bit is 0.
Source Storage Element Address – Bytes 10 and 11
This field shows the address of the last storage element from which the
cartridge was moved.
Primary Volume Tag Information – Bytes 12 through 47
When the PVolTag field (in the Element Status page described on page 19-5) is
set to 1, this field contains the volume tag (bar code label) information of the
cartridge in this storage location. The library supports eight bytes of volume
tag information, so only the first eight bytes reported are valid.
19.3.6 IMPORT/EXPORT ELEMENT DESCRIPTOR
If enabled, the library has the following I/E port elements (cartridge access
ports), for which it returns the following I/E element descriptor.
Magnum 224, T24, or SL 2U—The library has one I/E port.
Magnum 448—The library has two physical I/E ports, but you can “enable”
the library to use zero, one, or two I/E ports through the front panel.
0
The Source Storage Element Address field (bytes 10
and 11) is invalid
1
The Source Storage Element Address field (bytes 10
and 11) is valid
Bit
Byte
7 6 5 4 3 2 1 0
00 (MSB)
Element Address
(LSB)
01
02 Reserved INENAB EXENAB Access Except IMPEXP Full
03 Reserved
04 Additional Sense Code
05 Additional Sense Code Qualifier
06
Reserved
07
08
Kommentare zu diesen Handbüchern