A-2
SCSI REFERENCE 1014826
CHAPTER A—ERROR CODES
Ta b l e A - 1 lists library LCD error messages in alphabetical order.
If the corrective action in the table:
Refers you to the Product Manual for instructions (“See the Product
Manual”), go to www.tandbergdata.com.
Instructs you to reset the library or tape drive, go to “Resetting the library
and Tape Drive” on page 3-4 for instructions.
Does not correct the error, contact Tandberg Data Technical Support at
www.tandbergdata.com or your service provider.
Table A-1 Library LCD error messages
Error Message Description Corrective Action
Auto Cleaning The tape drive is performing
an automatic cleaning of the
tape drive using the cleaning
cartridge in the fixed
cleaning cell.
No action necessary.
Bad Cleaning Tape The tape drive has
determined that the
cleaning cartridge is not the
proper type for this tape
drive.
Replace the cleaning cartridge with one that is
compatible with this tape drive.
Use only LTO cleaning cartridges with LTO tape
drives.
Bad Configuration Configuration of drives does
not match drives found in
library.
1. Verify that the tape drive settings in the “Drive
configuration” menu match the type of
drive(s) installed. See the Product Manual.
2. Check the ADI interface cabling and
configuration.
3. Verify that the tape drive is operating
correctly.
Bad Download An error occurred during a
firmware upload to the
library.
The data downloaded for
the code update is incorrect.
1. Verify that you loaded the correct code. Do
not load firmware from one model of library
or library into another.
2. Reset the library and reload the correct
firmware.
If the error persists, contact Tandberg Data
Technical Support or your service provider.
Bootblock An error occurred during
firmware programing of the
library.
1. Verify that you loaded the correct code. Do
not load firmware from one model of library
or library into another.
2. Reset the library and reload the firmware.
If the error persists, contact Tandberg Data
Technical Support or your service provider.