JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
A-9
ERROR MESSAGES DISPLAYED ON THE LCD
Owned by Panel The library is executing a
command issued from
operator panel when a
command is issued from the
Remote Management utility
(see the Product Manual).
Wait until the library has finished its current
operation, then retry the operation.
Picker Ship-lock The robot could not move
because it may be locked in
place by the shipping key.
Remove the shipping key (see the Product
Manual).
POST Failed The library encountered an
error during its power-on
self-test.
1. Reset the library and retry the operation.
2. If the error persists, contact Tandberg Data
Technical Support or your service provider.
Power Fan The library has detected that
the power fan is not
operating properly.
1. Power cycle the library.
2. If the error persists, contact Tandberg Data
Technical Support or your service provider.
Reserve Failed The library could not reserve
the USB device resources.
1. Retry the operation.
2. Reset the library and retry the operation.
If the error persists, contact Tandberg Data
Technical Support or your service provider.
Reset Will Occur! When the operation
completes, the library will
reset itself as if a
power-cycle had occurred.
If the operation has not started, proceed with
the operation only if the reset will not cause a
problem.
If the operation is underway, no action is
necessary; the machine will reset itself.
Right Cable The library detected an error
with the right-side cable.
Contact Tandberg Data Technical Support or your
service provider.
Robot Empty The robot is unexpectedly
empty
1. Reset the library and retry the operation.
2. If the error persists, contact Tandberg Data
Technical Support or your service provider.
Robot Full The robot is unexpectedly
full
1. Reset the library and retry the operation.
2. If the error persists, contact Tandberg Data
Technical Support or your service provider.
SCSI Error An error occurred in the
ADI/SCSI interface.
Check the ADI/SCSI cabling and configuration.
See the Product Manual.
SCSI Timeout A timeout occurred in the
ADI/SCSI interface.
Check the ADI/SCSI cabling and configuration.
See the Product Manual.
Sequential Mode The library is set to operate
in Sequential Mode
Change to Random Mode and retry the
operation. See “Setting the Operation Mode” on
page 3-1.
Table A-1 Library LCD error messages (continued)