A-14
SCSI REFERENCE 1014826
CHAPTER A—ERROR CODES
For ease of reference:
Ascending ASC/ASCQ order—Ta b l e A - 3 lists all of the possible ASC, ASCQ,
Sense Key, and FSC values returned by the library, sorted in ascending
ASC/ASCQ order. Each combination of values is accompanied by one or
more cause codes and one or more error recovery procedure codes (ERPs).
Ascending FSC order—Ta b l e A - 4 o n p ag e A -2 0 lists the same information as
Ta b l e A - 3 , but it is sorted in ascending FSC order.
Error Recovery Procedures—The ERPs are described in Section A.3 on
page A-26.
Note: When two or more ERP codes are listed for a Fault Symptom Code,
attempt the recovery procedures in the order listed.
A.2.1 ERROR CODES IN ASCENDING ASC/ASCQ ORDER
Cause Key:
A= Application software L= Library
B= Bus (SCSI) O= Operator
D= Drive S= System
I= Information message T= Tape
Table A-3 REQUEST SENSE error information (ASC, ASCQ, FSC, and SK)
ASC
(byte 12)
ASCQ
(byte 13)
FSC
Sense
Key
Cause ERP SCSI Error Message and Description
00h 00h 00h 0h I 10 No error.
00h 06h 04h Bh O, B,
D, A, S
11 IO Process terminated. SCSI data
transfer aborted.
04h 01h 12h 02h O, B,
A, S
11 Logical Unit becoming ready.The library
is not ready, but is in process of becoming
ready.
04h 12h 12h 02h S, O 8 Library has been placed offline by the
system.
04h 83h 12h 02h O 11 Not Ready. Door open. The cartridge
access port door is open.
04h 89h 22h 02h O 11, 2 Not Ready. Console mode. An
application tried to issue commands to
the library while it was being controlled
from the Remote Management utility.
Kommentare zu diesen Handbüchern