Quantum LTO 2U Betriebsanleitung Seite 55

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 264
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 54
JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
5-1
5
INITIALIZE ELEMENT
STATUS WITH RANGE (37h)
5.1 ABOUT THIS COMMAND
The INITIALIZE ELEMENT STATUS WITH RANGE command causes the
library to attempt reading any bar code labels that were unreadable during the
automatic cartridge inventory. The information obtained by this command can
be returned to the initiator using the READ ELEMENT STATUS (B8h)
command.
Notes:
The average time required to complete this command is:
Magnum 224 or T24—12 seconds for a single cell and 120 seconds for 24 cells.
StorageLoader 2U—12 seconds for a single cell and 100 seconds for 20 cells.
Magnum 448—16 seconds for a single cell and 240 seconds for 48 cells.
For specifications for the bar code labels that can be used with the library, refer
to the Tandberg Data Bar Code Label Specification for LTO Ultrium Cartridges.
Bit
Byte
7 6 5 4 3 2 1 0
00 00110111
01 Reserved Fast Range
02 (MSB)
Starting Element Address
(LSB)
03
04
Reserved
05
06 (MSB)
Number of Elements
(LSB)
07
08 Reserved
09 Control
Seitenansicht 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 263 264

Kommentare zu diesen Handbüchern

Keine Kommentare