Quantum 1200 Series DAT Autochanger Betriebsanweisung Seite 131

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 294
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 130
SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-89
4.9.8 Logical Unit Control Page (18h)
The Logical Unit Control Page contains the logical unit control parameters for READ and WRITE
operations.
Figure 4-51. Logical Unit Control MODE SELECT Page — Data Format
Bit
Byte
7 6 5 4 3 2 1 0
0 PS SPF (0) Page Code (18h)
1 Page Length (06h)
2 Reserved Protocol Identifier (1h)
3 – 7 Reserved
Table 4-53. Logical Unit Control MODE SELECT Page — Field Descriptions
Field Name Description
PS Parameters Savable. Not supported. Must be set to 0.
SPF SubPage Format. Always set to 0. Indicates that the drive uses the page_0
page format.
Page Code Identifies the type of MODE SELECT page being transferred. A value of
18h identifies this as the Logical Unit Control Page.
Page Length Indicates the number of bytes in the page, excluding bytes 0 and 1. The
length is returned on MODE SENSE and must subsequently be set to the
same value when performing MODE SELECT. If the drive receives an
unexpected page length value, it returns a CHECK CONDITION status,
Sense Key set to ILLEGAL REQUEST.
Protocol
Identifier
A value of 1h indicates that this mode page applies to an SPI device. For
details, see SCSI Primary Commands – 3 (SPC–3).