MODE SENSE (6) / (10) Command (1Ah / 5Ah) SDLT 600 SCSI Interface Guide
4-108 January 2005 81-81200-02 REV A01
The 10-byte MODE SENSE command is required to request the vendor-specific EEPROM parameter
page due to the large amount of data that parameter page contains. MODE SENSE (10) can be used to
retrieve the other pages as well. Note that MODE SENSE (10) returns descriptor data in a different
format than MODE SENSE (6).
Figure 4-59. MODE SENSE (10) Command Descriptor Block — Data Format
Bit
Byte
7 6 5 4 3 2 1 0
0 Operation Code (5Ah)
1 Reserved LLBAA DBD Reserved
2 PC Page Code
3 SubPage Code
4 – 6 Reserved
7 – 8
(MSB)
Allocation Length
(LSB)
9 Control
Table 4-60. MODE SENSE Command Descriptor Block — Field Descriptions
Field Name Description
LLBAA Long LBA Accepted. Ignored. The drive does not support long LBA
format mode parameters.
DBD Disable Block Descriptors. When set to 0, the drive returns the block
descriptor data. When set to 1, the drive does not return block descriptor
information.
PC Page Control. Indicates the type of page parameter values the drive
returns to the host:
PC Type of Parameter Values
00b Report Current Values
01b Report Changeable Values
10b Report Default Values
11b Report Saved Values