3-8 January 2005 81-81200-02 REV A01
3.2.8 LOGICAL UNIT RESET (17h)
This message causes the drive to execute a logical unit reset function on the logical unit identified by
the last IDENTIFY message. The logical unit reset function is the same as would be performed
following a BUS DEVICE RESET message except only the logical unit selected is affected. The drive
enters the BUS FREE phase as part of processing this message and aborts all commands to the selected
logical unit.
Table 3-7. Drive’s Response to INITIATOR DETECTED ERROR Message
Bus Phase Drive Response
SELECTION The drive discards the INITIATOR DETECTED ERROR message and then
enters the BUS FREE phase.
COMMAND The drive discards any Command Descriptor Block bytes fetched from the
initiator, sets the Sense Key to ABORTED COMMAND, and sets the
Additional Sense Code to INITIATOR DETECTED ERROR MESSAGE
RECEIVED. The drive then sends the CHECK CONDITION status and the
TASK COMPLETE message and then enters the BUS FREE phase.
DATA The drive discards the INITIATOR DETECTED ERROR message, sets the
Sense Key to ABORTED COMMAND, and sets the Additional Sense Code to
INITIATOR DETECTED ERROR MESSAGE RECEIVED. The drive then
sends the CHECK CONDITION status and the TASK COMPLETE message
and then enters the BUS FREE phase.
STATUS The drive sends a RESTORE POINTERS message, returns to the STATUS
phase, resends the STATUS command, and continues the I/O process.
MESSAGE
IN
The drive discards the INITIATOR DETECTED ERROR message, sets the
Sense Key to ABORTED COMMAND, and sets the Additional Sense Code to
INITIATOR DETECTED ERROR MESSAGE RECEIVED. The drive then
sends the CHECK CONDITION status and the TASK COMPLETE message
and then enters the BUS FREE phase.