Appendix C Automatic Drive Cleaning
Selection of Cleaning Mode
96 ATL P2000 Series Automated Tape Library Users Guide
Tracking and selecting cleaning cartridges
Moving a cleaning cartridge to the drive
Determining when a cleaning cartridge has used all 20 of its
available cleaning cycles
Moving used up cartridges to the load port
Selection of Cleaning Mode
3
The cleaning mode is selectable from:
The diagnostic software
The touch screen GUI
A Mode Select command
The default cleaning mode is host-initiated. A Mode Select
command permanently changes the cleaning mode in the librarys
NVRAM, and is retained if the library power is cycled.
Diagnostic
Software
3
To change automatic cleaning mode from the diagnostic software
select
Config
:
Enable clean tape
- turns automatic cleaning mode on
Disable clean tape
- turns automatic cleaning mode off
Touch Screen GUI
3
To change automatic cleaning mode from the touch screen GUI,
select
Configuration/AutoClean
:
Enable
- turns automatic cleaning mode on
Disable
- turns automatic cleaning mode off