Chapter 5 Multi-Unit Commands
Calibrating the Libraries in a Multi-Unit Configuration
70 ATL P2000 Series Automated Tape Library User’s Guide
Figure 42 Configure
Multi-Unit
2
Press the Select button until the desired option is highlighted.
3
Using the arrow buttons, scroll through the available values for
the desired option.
4
When the desired value is displayed, press the Select button to
advance to the next option.
5
When you have finished making changes to the multi-unit
configuration options, press the Change button to save the
options and complete the configuration.
Calibrating the Libraries in a Multi-Unit Configuration
5
The Calibrate All PTMs command enables you to calibrate all pass
through mechanisms in all of the libraries in the multi-unit
configuration. Calibrate the libraries during the initial installation
and after any maintenance procedure.
To calibrate all library PTMs:
1
From the Master library in the multi-unit configuration, press
the Multi-Unit tab.
Tapes Service
Multi
Unit
Back Forward
Home
O
Configure: Multi-Unit
Change
Select
System
Off-line
Standby
Load Port
Stop
Library Unit:
SINGLE
Library Unit #:
# of Libraries:
LUN Config: SINGLE LUN
ATL