Quantum LTO 4 Betriebsanweisung Seite 66

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 98
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 65
Chapter 5 Specifications
Reliability Specifications
50 LTO-4 (Model B) Half-Height Tape Drive User’s Guide
Table 8 Reliability
Specifications
Mean Time Between
Failures
The mean time between failures (MTBF) for the internal drive is specified
at 250,000 hours minimum. This specification includes all power-on and
operational time but excludes maintenance periods. Operational time is
assumed to be 100% of the power-on time. Operational time is the time
the tape is loaded.
The MTBF for the tabletop drive power supply is 50,000 hours with the
unit operated at full load and 25°C.
Note: The MTBF rating does not represent any particular drive, but is
derived from a large database of test samples. Actual rates may
vary from unit to unit.
Mean Time to Replace The mean time to replace (MTTR) is the average time required by a
qualified service technician to diagnose a defective drive and to install a
Specification Description
Cartridge load/eject 50,000 cartridge load/eject cycles (no thread)
Error recovery and
control
Error correction code techniques
(C1 and C2 ECC)
Read-after-write (RAW)
Error monitoring and reporting (error log)
•Retry on
Mean time between
failures (MTBF)
250,000 hours MTBF at 100% duty cycle:
power applied and tape moving
continuously
(tabletop drive; 50,000 hours at full load and
25°C)
Mean time to replace
(MTTR)
Less than 30 minutes
Nonrecoverable error
rate
Less than 1 in 10
17
bits
Seitenansicht 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 97 98

Kommentare zu diesen Handbüchern